원래 장소:
심천, 광둥, 중국
브랜드 이름:
XingQi
1KV Low‑Voltage Heat‑Shrink Termination Kits / Heat‑Shrink Straight Joint Kits
Suitable for below 1kV rubber‑insulated cables
| Shelf‑Life & Storage |
| Product: 1kV Heat‑Shrink Termination / Straight Joint Kits |
| Long shelf‑life |
| Storage condition: ‑10℃ ~ 40℃, relative humidity less than 75% |
| Product Features |
| High mechanical strength |
| Suitable for various cable cross‑sections |
| Compact design |
| Excellent UV resistance and weather‑aging performance |
| Power‑on available immediately after installation |
| Easy and simple installation |
Selection Table for 0.6/1.0kV 4‑Core Heat‑Shrink Cable Intermediate Joints
| Product Name | Model Specification | Cable Cross‑section (mm²) |
|---|---|---|
| 4‑Core Intermediate Joint | XQ‑1/4.0 | 10‑16 |
| 4‑Core Intermediate Joint | XQ‑1/4.1 | 25‑50 |
| 4‑Core Intermediate Joint | XQ‑1/4.2 | 70‑120 |
| 4‑Core Intermediate Joint | XQ‑1/4.3 | 150‑240 |
| 4‑Core Intermediate Joint | XQ‑1/4.4 | 300‑500 |
The above quotation excludes hardware fittings and grounding wires.
0.6/1.0kV 4‑Core Heat‑Shrink Cable Straight Joint Selection — Multi‑Core Non‑Armored
![]()
Standard Kit Contents
| Medium‑wall heat‑shrink tube with adhesive |
| Waterproof sealing tape |
| PVC tape |
| Gauze strip |
| Protective gloves |
| Cleaning kit |
| Cleaning wipe |
0.6/1.0kV 4‑Core Heat‑Shrink Cable Straight Joint Selection — Multi‑Core Armored
![]()
| Medium‑wall heat‑shrink tube with adhesive |
| Waterproof sealing tape |
| PVC tape |
| Gauze strip |
| Grounding wire |
| Constant force spring |
| Cleaning kit |
| Cleaning wipe |
| Protective gloves |
0.6/1.0kV 4‑Core Heat‑Shrink Cable Straight Joint Installation — Multi‑Core Non‑Armored
![]()
| Step 1: Prepare the complete set of heat‑shrink tubes |
| Step 2: Prepare crimping tools (mechanical type, hydraulic type) |
| Step 3: Cable insulation length (measure and mark crimping length) |
| Step 4: Strip cable insulation (according to terminal size) |
| Step 5: Slide on the large heat‑shrink outer sheath tube |
| Step 6: Slide on the small heat‑shrink tube |
| Step 7: Fit terminals and complete crimping |
| Step 8: Slide on small heat‑shrink tubes and heat each until tightly wrapped around cables |
| Step 9: Slide on the large heat‑shrink tube and heat until tightly wrapped around cables |
0.6/1.0kV 4-Core Heat-Shrink Cable Straight Joint Installation — Multi-Core Armored
![]()
|
Step 1: Prepare the complete set of heat-shrink tubes
|
|
Step 2: Prepare crimping tools (mechanical and hydraulic type)
|
|
Step 3: Measure and mark the crimping length of cable insulation
|
|
Step 4: Strip the cable insulation according to the terminal size
|
|
Step 5: Slide on the large heat-shrink outer sheath tube
|
|
Step 6: Slide on the small heat-shrink tube
|
|
Step 7: Install and crimp the cable terminals firmly
|
|
Step 8: Slide on the small heat-shrink tubes and heat until tightly fitted to the cable
|
|
Step 9: Fix both ends of the grounding wire with constant force springs
|
|
Step 10: Slide on the large heat-shrink tube and heat until tightly fitted to the cable
|